Minimum attic access size ibc.
Or is a step ladder code compliant.
International building code 2015 ibc 2015.
According to the 2006 international residential code r807 1 attic access homes with combustible materials in the ceiling and roof construction must have an access to attic areas that exceeds 30 square feet and with a vertical height of 30 inches or greater.
When the access is located in a ceiling minimum unobstructed headroom in the attic space shall be 30 inches 762 mm at some point above the access measured vertically from the bottom of ceiling framing members.
International building code 2018 ibc 2018.
Clear headroom of not less than 30 inches 762 mm shall be provided in the attic space at or above the access opening.
From the finished floor to the ceiling shall not be included in any computation of the minimum area thereof.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
If the access is located in the ceiling the minimum unobstructed headrom above the opening must be 30 inches measured vertically at some point over the access.
2009 ibc from previous discussions i understand that stairs are not required to attics.
Minimum opening size the 2012 international residential code requires an attic access opening for attics with an area greater than 30 square feet and a vertical height in excess of 30 inches.
Access to mechanical appliances installed in under floor areas.
These specs are per r807 1 of the international residential code irc and the residential edition of the florida building code fbc.
Attic access r807 1 attic access.
306 3 appliances in attics.
See section m1305 1 3 for access requirements where mechanical equipment is located in attics.
When the access is located in a ceiling minimum unobstructed headroom in the attic space shall be 30 inches 762 mm at some point above the access measured vertically from the bottom of ceiling framing members.
In buildings with combustible ceiling or roof construction an attic access opening shall be provided to attic areas that exceed 30 square feet 2 8m2 and have a verti cal height of 30 inches 762 mm or greater.
The rough framed opening shall not be less than 22 inches.
Thanks from the 2009 imc.
Where wood shingles or shakes are used a minimum 1 4 inch.
762 mm shall be provided in the attic space at or above the access opening.