These values are in reference to mechanically attached insulation cover boards under.
Minimum required psi foam board for roof.
Rigid foam boards and are made.
Eps foam insulation may experience dimensional and property changes when it is exposed to temperatures greater than 167 f.
Maximum dimensional stability limit of 2 percent vs.
The existing standard of 4 percent which would allow a 96 inch board to expand contract 3 13 16inches.
Plus it s light weight easy to handle and easy to cut with a knife.
Extruded polystyrene closed cell foam astm c578 type iv 25 psi minimum shipped in poly wrapped units with individually wrapped or banded bundles.
Meets the requirements of astm c 1325.
The minimum insulation requirements for ceilings walls floors and foundations in new homes as listed in the 2009 2012 2015 and 2018 iecc and irc can be found in this table additional code requirements are listed on the compliance tab of this guide.
The panels need to fit together tightly to help prevent warm air from leaving the top of the building.
Minimum slope of per foot as required by the international building code ibc toward roof.
Exceptionally high compressive strength improves overall roof system performance cement board is able to withstand prolonged exposure to moisture and is ideal for systems where wind uplift and puncture resistance are a concern.
With an r value of 5 0 per inch of thickness the board increases the energy efficiency of your structures.
Composed of a lightweight cementicious core to provide exceptional impact resistance.
Ul certified for canada insulated roof deck assemblies construction no.
Insulation requirements by climate zone.
Rigid foam is produced in various size panels 4 ft x 8 ft 4ft x 4ft etc.
P 8000 pounds h 6 inches f c 2 500 psi e 57 000 2 500 2 850 000 psi u 0 15 k 360 psi for 1 inch eps.
Meet can ulc s126 can ulc s101 and can ulc s107.
Attach to deck board.
Grading the isocyanurate by compressive strength grade 1 compressive strength is minimum 16 psi grade 2 is minimum 20 psi and grade 3 is minimum 25 psi.
The minimum fastener pullout resistances for specific system the information listed in the chart below is for use with the referenced roof deck fastener type minimum pullout values and required penetration depths based on fasteners type.
After the roof deck is prepared the rigid foam boards need to be cut to size to fit snugly together on your roof.
K 360 psi 2 inches 180 pci.
In roofing type i eps material provides the dimensional stability and compressive strength necessary to withstand light roof traffic and equipment weight at reasonably high surface temperatures.