Minimum metal roof slope depends on the roof profile building design climate and site location.
Minimum slope corrugated metal roof.
Minimum pitch for corrugated metal roof just like other metal roofs the minimum pitch for a corrugated metal roof largely depends on the profile of the roof.
Corrugated roofing is a great material on traditional pitched roofs but it has severe limitations when the pitch gets below 5 degrees.
Lapped nonsoldered seam metal roofs without applied lap sealant must have a minimum roof slope of 3 12 25 slope.
Low slope roofs are not totally flat their roof slope generally ranges from 1 4 12 to 3 12.
The pitch is measured in inches of vertical rise per foot of horizontal run and the 5v crimp profile shown above requires a minimum slope of three in twelve or 3 12 3 inches vertically per 12 inches horizontally.
It is the recommended slope as there is no guarantee if you opt for flatter pitch than this.
The minimum slope for lapped non soldered seam metal roofs with applied lap sealant shall be one half unit vertical in 12 units horizontal 4 percent slope.
The minimum slope for lapped non soldered seam metal roofs without applied lap sealant shall be three units vertical in 12 units horizontal 25 percent slope.
That is why all roofing manufacturers recommend the 5 degree pitch as the minimum slope and they will not provide any guarantees if it is installed flatter than this.
In most occasions a pitch of three in twelve is preferred but this should also take into consideration the manufacturer s recommendations as well the unique condition of the corrugated metal roof.
Lap sealants shall be applied in accordance with the approved manufacturer s installation instructions.
The corrugated metal roof minimum slope is 5 degrees.
Low slope metal roofs require less material which reduces the overall load on the building s structure.
Lapped nonsoldered seam metal roofs with applied lap sealant must have a minimum roof slope of 1 2 12 4 slope.