So you would need to pick the right option as most regular standing seam metal roofs will require a roof pitch of 2 12 or even 3 12 at a minimum.
Minium roof pitch.
The following table provides the minimum required allowable roof slope for each type of roofing material mentioned in the code.
The 2 12 number is rise over run or two units of vertical for every 12 units horizontal.
Minimum roof slope roof pitch r905 3 2.
Shingles of all types need to have a slope to function properly.
That works out to about nine degrees if that works better for you.
You could also opt for a pvc flat roofing membrane.
The minimum roof slope allowed by code for any type of roof is in 12 applicable only to coal tar pitch roof systems.
Corrugated metal roofing has the same minimum pitch.
There is no standard universal roof pitch.
Clay and concrete roof tiles can only be installed on roof slopes of 2 1 2 12 or greater.
For the most part the minimum pitch for metal roof installations depends on what kind of material you are installing and the method in which the material is being fastened.
The minimum pitch for a roof is 1 4 12 which translates to 1 4 inch rise to 12 inches of run.
What is the minimum pitch slope of an asphalt shingle roof.
In the uk the typical house has a pitch between 40 50 although 45 should be avoided.
Minimum roof pitch for shingles it is important for shingle roofs to function properly and one method of ensuring that this is achieved is to observe the pitch requirements for the shingles.
The recommended minimum roof pitch for shingles is 2 12 or simply two units of vertical rise to every twelve units of horizontal span.
The minimum pitch is typically 3 12 meaning the roof should rise 3 inches for every 12 inches of horizontal foot.
The standard of lower pitch actually ranges between 1 12 to 5 12.
However you can only use this pitch with built up roofing or specialized synthetic roofing.
Anything above that will require you to put out higher cost because they are already considered as higher pitch.
There are some standing seam metal roofing options available from atas and other manufacturers that can be installed on a roof with pitch of 1 12.
The minimum pitch for metal roof shingles and lapped non soldered panels is 3 12.
The minimum requirement is 2 12.
The pitch is measured in inches of vertical rise per foot of horizontal run and the 5v crimp profile shown above requires a minimum slope of three in twelve or 3 12 3 inches vertically per 12 inches horizontally.